Stump length as related to atrophy and strength of the thigh muscles in trans-tibial amputees
E. ISAKOV * H. BURGER * M. GREGORIC * C. MARINCEK *
Abstract
Stump length and the thigh muscles strength of the amputated limb are among the major factors influencing outcome of prosthetic rehabilitation of trans-tibial amputees. In the present study the authors evaluated and compared the strength of quadriceps and hamstrings muscles of both limbs in trans-tibial amputees, as measured by means of an electrical dynamometer. The obtained results showed that the thigh muscles of the sound limbs are significantly stronger than those of the amputated limbs (p<0.01). The results obtained for amputees with shorter stumps were compared to those with longer stumps. In the group of amputees (n=9) with a stump shorter than 15.1 cm, values of peak torque (in isokinetic contraction) and maximal average torque (in isometric contraction) were significantly (p<0.5) weaker when compared to those (n=9) with a stump longer than 15.1 cm. The results obtained for amputees with a higher rate of thigh muscle atrophy were compared to those with lesser atrophy. In the group of amputees where muscle atrophy was accompanied by decrease in thigh girth of over 5.9 cm, muscles strength did not significantly decrease (p<0.5) as compared to amputees where thigh girth decrease was less than 5.9 cm. It is concluded that atrophy of the thigh muscles of trans-tibial amputees is accompanied with a significant decrease in strength. In amputees with a short stump, the short lever action provided by the stump interferes with the ability of the thigh muscles to control the prosthesis efficiently during daily activities such as standing and walking.
Introduction
A short stump might interfere with success in prosthetic rehabilitation of trans-tibial amputees. An adequately long stump provides the amputee with a good proprioceptive feedback (Guerts and Mulder, 1992) resulting from both a large contact surface and good stability of the stump-socket unit. These factors enable good standing and walklng in these patients (Isakov
et al
., 1985; Isakov
et al
., 1994; Seliktar
et al
, 1980). When the stump of a trans-tibial amputee is short and the transverse and longitudinal dimensions are almost similar, the stump acquires a round shape and may become unstable inside the prosthetic socket (Seliktar
et al
., 1980; Nissan, 1977). As a result, instability of the stump-prosthesis complex creates shear forces with resulting pain and/or blisters or friction sores which prevent prosthesis usage for a long period of time. Researchers have studied the forces acting on a short trans-tibial stump (Sanders
et al
., 1992; Lilja
et al
., 1993) and various prosthetic solutions have been suggested for improving stability of the stump-socket unit and the quality of standing and walking (Isakov
et al
., 1992; Pritham, 1979).
It is suggested that the stump of trans-tibial amputees is less active in the dally functions of standing and walking. In fact, atrophy of the thigh muscles of the amputated limb is often observed among such amputees, a finding evident from quadriceps muscle biopsies (Renstrom
et al
., 1983). Evaluation of standing balance activity of both limbs in trans-tibial amputees showed that the foot-ground reactive forces generated by the amputated limb are smaller (Isakov
et al
., 1992; Geurts and Mulder, 1992). Analysis of gait in trans-tibial amputees showed a shorter body weight bearing stance phase on the amputated limb as well as asymmetry in other gait phases (Baker and Hewison, 1990). It can therefore be assumed that reduced involvement and activation of the amputated limb muscles in activities such as standing and walklng results in disuse atrophy of the thigh muscles of the affected limb. The present study aimed at evaluating whether the stump length and thigh muscles atrophy are related to the strength of the thigh muscles in trans-tibial amputees.
Subjects
Eighteen volunteers, 6 female and 12 male, with trans-tibial amputation were assessed (
Table 1
). Their average age was 45.7±14.7 years (range, 27 to 74 years). The mean time from the amputation to the present study was 13.4±14.4 years (range, 1 to 46 years). Causes for amputation were; traffic injury 6, work accident 5, war injury 1, diabetes mellitus 2, peripheral arterial disease 1, tumour 1, infection 2.
Subjects' mean stump length was 15.1±3.2 cm (range, 8.5 to 21 cm). The thigh girth at 18 cm above the tibial tuberosity of the amputated limb was smaller compared with the contralateral limb (5.9±2.5; range: 2-12.5 cm). At 30 cm above the tibial tuberosity the difference was 4.0±2.9 cm (range: 0-10.5 cm). All subjects were fitted with a patellar tendon-bearing prosthesis. They were using their prostheses for the whole day and were able to walk continuously a mean distance of 2.5±1.4 km. No subject had any knee joint contracture or complaints of knee or stump pain during the test.
Methods
Measurements
In each subject, measurements of the thigh girth were taken at an equal distance from the tibial tuberosities of both legs, proximally 18 and 30 cm. Measurements were taken by one of the team members using a standard tape measure, a method found reliable for measuring circumference of the lower limb (Renstrom
et al
., 1983). Measurements were performed in the lying position with knees extended and thigh muscles relaxed.
Stump length was measured while the knee was in 90 degrees of flexion. The upper reference point was the medial femoro-tibial inter-condylar line and the lower point the stump tip.
Instrumentation
The isokinetic concentric and eccentric and isometric muscle torques of the knee extensors and flexors were measured on-line with Biodex Model B-2000 (Biodex, NY, USA) (Wilk and Johnson, 1988; Thompson
et al
., 1993). A special lever was constructed to meet with the special needs of the tested stump. For each subject the lever arm was adjusted to rest at the same distance from the lower pole of the patella in both limbs. In order to eliminate the effect of gravity, the torque due to the mass of the limb was determined and then added to measured torque values when working against gravity and subtracted from the torque values when working with gravity. The dynamometer was calibrated according to the manufacturer's recommendations once a week.
Measured parameters:
Muscular efficiency was evaluated by measuring the quadriceps and hamstrings isokinetic concentric and eccentric and isometric strength. Peak torque (Nm) is the highest value of torque developed throughout the range of motion curve. Maximal average torque (Nm) is the greatest average torque produced for a repetition within a set.
Procedure
Positioning:
The patients were seated with hip joints angle of 90-100 degrees. Stabilisation straps were placed across the trunk, around the waist, and mid-thigh of the limb to be tested. The anatomical axis of the knee joint was visually aligned with the axis of rotation of the dynamometer.
Learning phase:
Prior to each test, subjects were instructed and allowed to try the dynamometer. The differences between concentric, eccentric and isometric were explained. The subjects then performed submaximal contractions in order to be acquainted with the exercise.
Test sequence:
The test procedure consisted of five consecutive isokinetic concentric contractions for the quadriceps and hamstrings muscle groups, followed by five eccentric contractions with five minutes rest. The constant angular velocity was established at 60 degrees per second. Following 5 minutes rest, each subject performed five consecutive isometric contractions of 5 seconds each. The quadriceps contraction was evalued at 45 degrees of flexion and the hamstrings contraction at 60 degrees of flexion. Subjects were asked to perform their maximal effort and verbal encouragement was provided to each subject throughout the test session. Statistical analysis of the significance of the results was performed using the paired t-test and the level of significance was set at p<0.05.
Results
The means and standard deviations of values (Nm) obtained for the quadriceps and hamstrings of both limbs are detailed in
Table 2
. Results relate to the three different strength measurements during isokinetic concentric, isokinetic eccentric (peak torque) and isometric contractions (maximal average torque). Values obtained in the muscles of the amputated limb were significantly smaller compared with the sound limb muscles (p<0.01). The test subjects were divided into two groups. The first group of nine amputees included those with stump length less than 15.1 cm, the second group of nine amputees had a stump length of more than 15.1 cm. Values of torques obtained in these two groups are detailed in
Table 3
. In the group with the shorter stump, quadriceps (eccentric contraction) and hamstrings (concentric contraction) strength was significantly smaller when compared to the group with a longer stump (p<0.05). All other values in the group with the shorter stump were also smaller however less significantly (p<0.3).
Atrophy of the amputated thigh muscles as related to thigh girth differences were considered also. The subjects were divided into two groups according to girth differences obtained 18 cm above the tibial tuberosity. In the first group of nine amputees, thigh girth mean differences were greater than 5.9 cm and in the second group thigh girth mean differences were less than 5.9 cm. The mean of muscle torque in both groups were calculated and compared (
Table 4
) showing the differences in muscles strength between these groups to be insignificant (p<0.5).
Discussion
Although amputation surgery is a constantly improving process, there are still cases where it is not possible to construct a sufficiently long trans-tibial stump. In the present study, the amputees' average length of the stump was 15.1 cm (range: 8.5-21 cm) while others report an average length of 16 cm with a range between 10 and 25 cm (Persson and Liedberg, 1983). Stump length is the major factor determining stability of the BK stump inside the prosthetic socket and consequently the quality of standing and walking (Seliktar
et al
, 1980; Nissan, 1977; Isakov
et al
., 1992). Other important factors which influence the rehabilitation outcome of amputees are an optimal prosthesis fitting and strength of the quadriceps and hamstrings muscles controlling the knee of the affected limb (Klingenstierna
et al
., 1990).
The authors evaluated the isokinetic and isometric strength of the amputated limb thigh muscles by means of a dynamometer. The advantages of this method when compared to manual muscle testing (Nicholas
et al
., 1978; Iddlings
et al
, 1961) are that it provides an objectively reproducible and reliable test (Steiner
et al
, 1993; Wilke and Johnson, 1988; Thompson
et al
, 1993). The obtained results for peak torque in isokinetic concentric and eccentric and for maximal average torque in isometric contraction were significantly smaller in the amputated limbs when compared to the sound limbs. The strength of thigh muscles of amputees with a short stump was compared with those with a longer stump. The obtained results indicate clearly a decrease in strength of the amputated limb thigh muscles in trans-tibial amputees with a short stump as evaluated under the described conditions. It is therefore assumed that the inefficient lever action provided by the short trans-tibial stump, compromises the performance ability and level of the knee muscles activity during prosthesis usage.
Thigh muscle atrophy was determined by measurements of thigh girth. The measuring level was chosen where differences between thigh girth were greater, 18 cm proximal to the tibial tuberosity. Two groups of amputees were compared; those where thigh girth differences were greater than 5.9 cm and those with a difference smaller than 5.9 cm. Comparing values of muscles strength measured in these two groups, a general decrease in strength was noticed among those with a greater thigh muscles atrophy nevertheless, differences were not significant.
In conclusion, although most trans-tibial amputees manage their activities of daily living and conduct a fairly active life, strength of the amputated limb thigh muscles was found significantly reduced, especially in amputees with a short stump. In so far as the ultimate goal in the rehabilitation of amputees is to return the patient to an acceptable level of function, it is recommended that the amputee should be trained and encouraged in self strengthening exercises for the amputated limb thigh muscle. Stronger muscles will improve standing balance and quality of gait, especially among those with a short stump.
Acknowledgement
The authors would like to thank Mr. Tomsic Igor for his valuable help with the Biodex measurement and to Mr. Bevetek Tomaz for his assistance during testing procedures.
References:
- Baker PA, Hewison SR (1990). Gait recovery pattern of unilateral lower limb amputees during rehabilitation. Prosthet Orthot Int 14, 80-84.
- Geurts ACH, Mulder TW (1992). Reorganisation of postural control following lower limb amputation: theoretical considerations and implications for rehabilitation. Physiotherapy Theory Practice 8, 145-157.
- iddlings D, Smith L, Spencer W (1961). Muscle testing. Part 2: reliability in clinical use. Phys Ther Rev 41, 249-256.
- Isakov E, MIZRAHI J, Ring H, SusAK Z, Hakim N (1992). Standing sway and weight-bearing distribution in below-knee amputees. Arch Phys Med Rehabil 73, 74-178.
- Isakov E, MIZRAHi J, SusAK Z, Ona I (1992). A Swedish knee-cage for stabilizing short below-knee stumps Prosthet Orthot Int 16, 114-117.
- Isakov E, Mizrahi J, Susak Z, Ona I, Hakim N (1994). Influence of prosthesis alignment on the standing balance of below-knee amputees. Clin Biomech 9, 258-262.
- Isakov E, Susak Z, Becker E (1985). Energy expenditure and cardiac response in above-knee amputees while using prostheses with open and locked knee mechanism. Scand J Rehabil Med 12,108- 111.
- klingenstierna U, renstrom P, grimby G, morelli B
- (1990). Isokinetic strength training in below-knee amputees. Scand J Rehabil Med 22, 39-43.
- Luja M, Johansson T, Oberg T (1993). Movement of the tibial end in a PTB prosthesis socket: a sagittal X-ray study of the PTB prosthesis. Prosthet Orthot Int 17,21-26.
- Nicholas J, Sapega A, Kraus H, Webb J (1978). Factors influencing manual muscle tests in physical therapy: the magnitude and duration of force applied. J Bone Joint Surg 60A, 186-188,
- Nissan M (1977). A simplified model for the short-below-knee stump. J Biomech 10, 651-658.
- Persson BM, Liedberg E (1983). A clinical standard of stump measurement and classsification in lower limb amputees. Prosthet Orthot Int 7, 17-24.
- Prttham CH (1979). Suspension of the below-knee prosthesis: an overview. Orthot Prosthet 2,1-19.
- Renstrom P, Grimby G, Morelli B, Palmertz B (1983). Thigh muscle atrophy in below-knee amputees. Scand J Rehabil Med 15, 150-162.
- Sanders JE, Daly CH, Burgess EM (1992). Interface shear stresses during ambulation with a below-knee prosthetic limb. J Rehabil Res Dev 29(4), 1-8.
- Seliktar R, Bar A, Susak Z, Najenson T (1980). A prosthesis for very short below-knee stumps. Orthot Prosthet 34(1), 25-35.
- Steiner LA, Harris BA, Krebs DE (1993). Reliability of eccentric isokinetic knee flexion and extension measurements. Arch Phys Med Rehabil 74, 1327-1335.
- Thompson CR, Paulus LM, Timm K (1993). Concentric isokinetic test-retest reliability and testing interval Isokinetics Exerc Sci 3, 44-49.
- Wilk KE, Johnson RD, Levin B (1988). The reliability of the Biodex B-2000 isokinetic dynamometer (abstract). Phys Ther 68, 792-795.
|