Modified fracture brace for tibial fracture with varus angulation: a case report
S.F.T. Tang * T.L.S. Au * A.M.K. Wong * M.Y. Lee *
Abstract
Sarmiento introduced the functional fracture brace for the management of tibial shaft fracture in 1963. However, tibial angulation with varus deformity cannot be prevented or corrected by such a device. In this paper, a case of tibial shaft fracture with varus angulation treated with a modified below-knee fracture brace was reported.
Introduction
The goals of management in tibial shaft fracture are to obtain union, to preserve ankle and knee motion, and to maintain alignment. Management of tibial shaft fracture by functional fracture bracing has been known for many years (Sarmiento, 1967 and 1970; Sarmiento et al., 1980). However, varus angulation is a frequent occurrence especially in the presence of an intact fibula (Sarmiento et al., 1989; Teitz et al., 1980).
In the management of tibial fracture, non-operative treatment may offer the advantage of low incidence of infection (Sarmiento et al., 1989). In 1963, Sarmiento introduced the functional cast for the management of fracture of the tibial shaft (Sarmiento et al., 1967), and eventually modified the procedure to the use of a prefabricated functional fracture brace. His serial reports showed such bracing was an effective alternative for treatment of selected fractures of the tibia (Sarmiento, 1970; Sarmiento et al., 1984; Sarmiento et al., 1989). A fracture brace of such type is particularly well suited for the weather in Taiwan. Many patients with a tibial shaft fracture treated by cast fixation developed skin problems due to humid weather. However, shortening of the injured limb and the tendency for tibial angulation may still occur, especially with an intact fibula. This device cannot prevent or correct tibial angulation. Moreover, such complications were also observed by other investigators. Some researchers even concluded that single tibial fractures with an intact fibula presented an insidiously dangerous fracture pattern, particularly in patients more than twenty years old (Teitz et al., 1980). When tibial angulation occurs during bracing, the brace should be discontinued and replaced by casting. Sometimes, tibial angulation should be corrected by surgical intervention (Bohler, 1965; Fernadez-Palazzi, 1969; Lottes, 1965; Sharma, 1972; Sorensen, 1969).
Case Presentation
A 30-year-old woman fell down accidentally in downhill skiing on December 25, 1990. She was found to have a closed comminuted fracture at the lower third of the right tibial shaft with medial malleolar fracture (Fig. 1 and Fig. 2). A temporary long-leg cast was given for travelling, and changed to a functional fracture brace of Orfit material on the fifth day after injury. However, a varus angulation of 10° in the right tibia was noted ten days later after bracing (Fig. 3). To reduce and to maintain the alignment of the tibia, a modification in moulding technique of the fracture brace was introduced.
Modification
A wooden rod (1.5cm in diameter, 23cm in length, 45gm in weight) was embedded at the under-side of the anterior shield of the brace, just between the tibia and fibula. Trimming of the rod was undertaken for comfortable fitting. The ankle was fixed in the neutral position for the medial malleolar fracture. The brace was moulded directly to the right lower leg using thermoplastic material (Orfit, Luxilon, 3.2mm in thickness, 55-60°C in moulding temperature) after the rod was fixed snugly between the tibia and fibula by elastic bandage. The tightness of the brace was adjusted by five velcro straps at different positions (Fig. 4, Fig. 5, and Fig. 6).
Results
Roentgenographic examination showed a significant immediate correction of the varus angulation of the tibia to less than 5° by fitting of this modified fracture brace (Fig. 7). The patient walked with axillary crutches with nonweight bearing of the right leg until the sixth week. Satisfactory bridging callus formation with sound alignment of the tibia was found in X-ray film at the twentieth week (Fig. 8), and the patient could walk with full weight bearing on the leg without pain. At the thirty-second week, the fracture brace was discarded. She had full range of motion at the right knee and ankle. Mild to moderate degree of muscle atrophy in the right leg was noted, but still with good muscle power. Radiographs taken one year after of the right tibia showed nearly complete bone healing with no late varus deformity (<5°) at the fracture site (Fig. 9). All joints of the right lower limb had full range of motion and no shortening of leg length was noted.
Discussion
In this paper, the patient developed a varus deformity after fitting with conventional fracture brace for ten days. However, the angulation was successfully controlled by the modified fracture brace with satisfactory maintenance of alignment. The time course for subsequent bone healing and clinical recovery for the patient was consistent with those results reported by Sarmiento in 1989. She ambulated well consequently without any significant sequelae.
The modified fracture brace proposed in this paper was developed from the authors' successful applications of plastic anterior ankle foot orthoses (AFO) (Wong et a.l, 1992). The fracture brace is the combination of the anterior and posterior leaf AFO (Teufel style orthosis) together as one unit (Lehmann et al., 1985). The length of that brace anteriorly and posteriorly is similar to that of the patellar tendon-bearing othosis (Fishman et al., 1985). This design might conform to the hydraulic principles which prevent shortening of the injured limb (Sarmiento, 1970). The embedding of the light wooden rod at the lateral underside of the anterior leaf AFO provides a constant transverse strain onto the varus angulation. It is believed that it was this straining effect that prevented the recurrence of varus deformity.
Although satisfactory results were achieved in this case with the modified fracture brace. Further investigation is needed to prove the consistency of the result.
References:
- Bohler J (1965). Treatment of nonunion of the tibia with closed and semiclosed intramedullary nailing. Clin Orthop 43, 93-101.
- Fernandez-Palazzi F (1969). Fibular resection in delayed union of tibial fractures. Acta Orthop Scand 40, 105-118.
- Fishman S, Beroer N, Edelstein JE, Springer WP (1985). Lower limb orthoses. In: Atlas of orthotics: biomechanical principles and application./2nd edition./American Academy of Orthopaedic Surgeons.-St. Louis: CV Mosby. pl99-237.
- Lehmann JF, Condon SM, De Lateur BJ, Smith JC (1985). Ankle-foot orthoses: effect on gait abnormalities in tibial nerve paralysis. Arch Phys Med Rehabil 66, 212-218.
- Lottes JO (1965). Treatment of delayed or nonunion fractures of the tibia by a medullary nail. Clin Orthop 43, 111-128.
- Sarmiento A (1967). A functional below-the-knee cast for tibial fractures. J Bone Joint Surg 49A, 855-875.
- Sarmiento A (1970). A functional below-the-knee brace for tibial fractures: a report on its use in one hundred thirty-five cases. J Bone Joint Surg 52A, 295-311.
- Sarmiento A, Gersten LM, Sobol PA, Shankwiler JA, Vangsness CT (1989). Tibial shaft fractures treated with functional braces: experience with 780 fractures. J Bone Joint Surg 71B, 602-609.
- Sarmiento A, Solo PA, Sew Hoy AL, Ross SDK, Racette WK, Tarr R (1984). Prefabricated functional braces for the treatment of fractures of the tibial diaphysis. J Bone Joint Surg 66A, 1328-1339.
- Sharma MA (1972). Partial resection of the fibula in delayed union of the tibia (abstract). J Bone Joint Surg 54B, 201.
- Sorensen KH (1969). Treatment of delayed union and non-union of the tibia by fibular resection. Acta Orthop Scand 40, 92-104.
- Teitz CC, Carter DR, Frankel VH (1980). Problems associated with tibial fractures with intact fibulae. J Bone Joint Surg 62A, 770-776
- Wong AMK, Tang F-T, Wu S-H, Chen C-M (1992). Clinical trial of a low-temperature plastic anterior ankle foot orthosis. Am J Phys Med Rehabil 71, 41-43.
|